INS-11013-1 | Tonometer Goldmann-R Type
INS-11013-1 | Tonometer Goldmann-R Type

INS-11013-1 | Tonometer Goldmann-R Type

Brand: Opti+
Color: Default Title
SKU: INS-11013-1
Descargar Folleto Download Manual
Comparar Hacer una pregunta

Hacer una pregunta

* Campos obligatorios

Guía de tallas Compartir
Descripción

The INS-11013-1 Goldmann Applanation Tonometer (R-Type) is designed for accurate intraocular pressure measurement during slit-lamp examinations. Its R-Type tower-mounting configuration allows convenient integration with compatible slit lamps, providing a stable and efficient solution for routine IOP evaluation.


Outstanding Features

Goldmann Applanation Measurement

The INS-11013-1 uses the established Goldmann applanation method to measure intraocular pressure while the patient is being examined under a slit lamp.

R-Type Tower Mounting

The R-Type configuration is specifically designed for installation on compatible tower-style slit lamps, providing stable positioning and convenient access during examinations.

Wide Measurement Range

The tonometer provides an intraocular pressure measurement range from 0 to 80 mmHg, supporting routine examinations and the evaluation of elevated IOP.

Precise Scale Graduation

A measurement graduation of 0.5 mmHg allows the practitioner to obtain detailed intraocular pressure readings.

7 mm Biprism

The instrument incorporates a 7 mm biprism designed for Goldmann applanation measurements under slit-lamp illumination.

Controlled Biprism Movement

The biprism provides a 3 mm movement range for controlled positioning during the examination.

Compact Clinical Design

Its compact construction allows the tonometer to remain conveniently mounted on the slit lamp without unnecessarily occupying examination-room space.


The Opti+ INS-11013-1 Goldmann Applanation Tonometer provides precise IOP measurement, convenient R-Type tower mounting, and a wide 0-80 mmHg measurement range for dependable clinical examinations.


Technical Specifications

TECHNICAL DATA
Instrument Type Goldmann applanation tonometer
Model YZ30
Configuration R-Type
Measurement Method Goldmann applanation
Measurement Application Intraocular pressure measurement under a slit lamp
Slit-Lamp Compatibility Compatible tower-style slit lamps
Measurement Range 0 to 80 mmHg
Measurement Graduation 0.5 mmHg
Biprism Diameter 7 mm
Biprism Movement Range 3 mm
PHYSICAL DATA
Dimensions 10 × 5 × 4 in (25 × 13 × 10 cm)
Weight 2 lb (1 kg)

Productos vistos recientemente